Get 2008-2009 Basic and Clinical Science Course: Section 10: PDF

By George A. Cioffi, MD

ISBN-10: 1560558830

ISBN-13: 9781560558835

This part underwent significant revision for the 2008-2009 edition.Topics mentioned comprise the epidemiologic elements of glaucoma; hereditary and genetic elements; intraocular strain and aqueous humor dynamics; scientific overview; scientific administration of and surgical treatment for glaucoma. This version includes up to date tables and revised pictures, in addition to quite a few new photos illustrating either ailment entities and surgical recommendations.

Show description

Read or Download 2008-2009 Basic and Clinical Science Course: Section 10: Glaucoma (Basic and Clinical Science Course 2008-2009) PDF

Similar ophthalmology books

2011-2012 Basic and Clinical Science Course, Section 7: - download pdf or read online

Info the anatomy of the orbit and adnexa, and emphasizes a pragmatic method of the review and administration of orbital and eyelid problems, together with malpositions and involutional adjustments. Updates present details on congenital, inflammatory, infectious, neoplastic and hectic stipulations of the orbit and accent buildings.

Read e-book online Clinical Ocular Prosthetics PDF

This can be the 1st textbook to provide a finished account of ocular prosthetics and the proof used to underpin and help this box of healthcare. It does so by means of bringing jointly info from ophthalmology, prosthetic eye and make contact with lens literature, and from specialists actively engaged in those fields.

Harley’s Pediatric Ophthalmology - download pdf or read online

For over 3 many years, Harley’s Pediatric Ophthalmology has been the best reference in pediatric ophthalmology. during this 6th variation it gives you much more of the distinct and functional assurance that has made it the main depended on source within the field. Completely revised, its new full-color layout can help the reader determine pathologies and preserve key evidence.

Get LASIK: Principles and Techniques PDF

Lucio Buratto, MD and Stephen F. Brint, MD have collaborated to advance an authoritative source on LASIK. they've got built this textbook to collect the very most recent info in a transparent and finished structure. all through this booklet you need to achieve a superior starting place and figuring out of the LASIK technique, in addition to various person equipment and viewpoints at the surgical procedure.

Additional info for 2008-2009 Basic and Clinical Science Course: Section 10: Glaucoma (Basic and Clinical Science Course 2008-2009)

Sample text

The red line posterior to the trabecular mesh. venous pressure resulting in blood reflux into of G. A. Cioffi. MD.! either radially along the iris or circumferentially (in a serpentine manbody face. Vessels that cross the scleral spur to reach the trabecular meshwork are usually abnormal (Fig 3-6). The vessels seen in Fuchs heterochromic cyclitis are fine, branching, unsheathed, and meandering. Patients with neovascular coma have trunklike vessels crossing the trabecular meshwork. Contraction leads to PAS formation.

Portable electronic applanation devices employ a disposable cover,which should be replaced immediately after each use. The Schiotz tonometer requires disassembly to clean both the plunger and the footplate. Unless the plunger is clean (as opposed to sterile), the measurements may be falsely elevated because of increased friction between the plunger and the footplate. CHAPTER 2: Intraocular Pressure and Aqueous Humor Dynamics. 31 A pipe cleaner can be used to clean the inside of the footplate, removing tears and any tear film debris.

In applanation tonometry, the cornea is flattened, and lOP is determined by measuring the applanating force and the area flattened (Fig 2-4). 06 mm diameter. At this diameter, the resistance of the cornea to flattening is counterbalanced by the capillary attraction of the tear film meniscus for the tonometer head. Furthermore, the lOP (in mm Hg) equals the flattening force (in grams) multiplied by 10. A split-image prism allows the examiner to determine the flattened area with great accuracy. Fluorescein in the tear film is used to outline Direction of_ observer's view -- Area of corneal Housing flattening n 1 Adjustment knob A Meniscus width B t - - - - - - - - - -~.

Download PDF sample

2008-2009 Basic and Clinical Science Course: Section 10: Glaucoma (Basic and Clinical Science Course 2008-2009) by George A. Cioffi, MD


by Jeff
4.4

Rated 4.53 of 5 – based on 8 votes

admin